Flow sensor or flowmeter?

flow sensor

Flow sensor or flowmeter, that’s the question 😉

To be honest, when we would be having a conversation about your application, it doesn’t matter wether the needed instrument is referred to as flowmeter or flow sensor. We will both know what we mean and come to the right conclusion.

A different situation is the moment that an engineer starts searching the internet for a flow sensor. Chances are high that the search result returns a sensor which has no proper measuring capability. A disappointing testresult is to be expected.

When to choose for a flow sensor?

Flow verification

A flow sensor will return a signal when flow is detected. So if you look for a flow-verification, a sensor is sufficient. You may have already a signal that the pump is running, but due to numerous aspects in the piping system, it is well possible that the intended flow is not happening. A simple sensor will provide certainty!

High-Low flowrate

In your system there might be situations where a high or a low flowrate occurs, a sensor might be ccurate enough to properly determine which of the stages is actual. Again a good sensor-application.

When is a flowmeter the better option?

Input for a controlled flow

In equipment there are often liquid cooling circuits in which a nominal flowrate is designed. In process-circumstances the actual flowrate may differ from the nominal value.
The actual flowrate is converted in real-time to an analogue value (often 4-20 mA range).
This signal acts as a reference for adjusting the pump.
The result is a flowrate that is continuously at the designed value, providing maximal thermal stability to the equipment.
MIB’s Flowmax 44i is a commonly used instrument in piping up to Dn25 m.
Higher flowrates are handled by Flowmax 54i.

Qualification of a pump

Imagine your engineers designed a new setup which will be the basis of all your machines in the future.
Do you trust the specs on paper, or would a validation make sense? In most industries qualification and validation are mandatory.
A test-bench with an accurate flowmeter is part of that.

Volumetric / Batch-control

In applications where a certain volume needs to be dispensed or transported, a flowmeter is the right instrument to measure the volume which has passed.
Flowmax has the option to define the batch-volume and when this amount is measured, a digital output signal informs the system that valves can be shut and pumps turned off.

Volumetric control for financial transactions

When purchasing fuel, the dispenser registers the amount of dispensed.
The measured volume is used to initiate the financial transaction.
The instrument to use here is not a flowensor and not a normal flowmeter, it requires MID-approval.
Flowmeister is happy to advise you on this topic!
Sorry we can’t fill it in with the range of Flowmax instruments.

What’s your application? Get advised and receive a quote !

Your instrument has been tested, which is certified with the delivery. Optionally, a 3- or 8-point calibration-certificate can be ordered to prove the exact accuracy.

Before you submit:

you may trust an honest advise. If FlowMax is not your best possible solution, I will explain you why that is.

Flowmax products

Previous Image
Next Image

info heading

info content

Trust by design

When asked what is the most important property of flow measurement, almost every customer answers “ACCURACY”.
Understandable, you would rather not invest in an inaccurate instrument to control your pocess.

When the conversation continues, very often it appears that the automated production system is not too dependent on accuracy of the flowmeasurement itself.
The product-quality is more influenced by process-aspects that cause wrong readings coming from the meter.
In certain circumstances, it appears that the readings cannot be trusted.
The design of Flowmax ultrasonic flowmeters is made to be trusted.

Reliability is the key …

Some physical examples of improved reliability:
– An open bore without obstacles is never causing disturbances, cavitation
– No moving or rotating parts in the liquid which may wear out or get stuck
– Moving or rotating parts may release particles in the liquid
– No gaps, dead space or seals to affect product quality or leakage
– Air bubble detection immediately warns for detected bubbles
– Robust measuring tube, physically stable measuring unit
– Solid sensor mounting, not sensitive to environmental vibrations

All reliability features apply equally to Industrial and Single Use versions!

… and Accuracy matters

Of course accuracy matters.
Third to Reliability and Speed, the measuring accuracy is one of the selling features of Flowmax ultrasonic flowmeters!
Our biggest advantage is the fact that the calibrated measuring tube is inserted into your flowpath.
Calibration data is stored in the measuring tube.
This simple fact ensures that the performance in your system is comparable to the performance in the manufacturers’ calibration setup!
What else would you need?

What makes your application special?

Your instrument has been tested, which is certified with the delivery. Optionally, a 3- or 8-point calibration-certificate can be ordered to prove the exact accuracy.

Before you submit:

you may trust an honest advise. If FlowMax is not your best possible solution, I will explain you why that is.

Disposable flowmeter

disposable flowmeter

 

The Disposable Flowmeter is a niche-product of which multiple variants have become available in the market.
Diversity in the available solutions is needed, there simply is no universal solution with only advantages.
Your application, demands and wishes, determine which type of single use flowmeter is the best match.
Below I like to mention some aspects that are to be considered in the selection-process.

Demands and wishes

When starting to think about specifications, a number of aspects will come to your attention.
In this phase it is useful to separate the absolute demands from the more ‘soft’ wishes.

Doing this will help you in a later stage where you might be forced to choose between possible solutions.
An example is de flowrange of the instrument.
Each application will hae a lower limit and an upper limit.
-> If the lower limit is a demand, please store it as such in your list.
-> If a higher max flowrate may be useful in the future, write it down as a wish.
It may very well be that a high flowrate instrument is available, but doesn’t offer the required accuracy in its lower measuring range.

 

Accuracy

Each type of instrument measures differently and has a different deviation.
Each method has in its physical form a maximum achievable accuracy. Deviation from the nominal measured value results in a process-deviation.

It’s up to you to determine wich level of accuracy is required.
When comparing, please be advised to ensure the unit of measure in which accuracy is expressed.
A 1% deviation of Full Scale (FS) can be completely different from a 1% of  Measured Value (MV). This topic is further detailed in another chapter.
A high-end instrument such as Coriolis or Ultrasonic will prove its accuracy on the certificate of calibration.

Wetted parts

The so called ‘wetted parts’ are all the internal parts of the disposable flowmeter that actually are in contact with the measured medium.
In the example of a turbine-meter these are: housing, turbine-blades, shaft, bearings and possible sealing material.
An electromagnetic flowmeter already has less wetted parts, but will always have a housing, metal electrodes and seals.
Coriolis- and ultrasonic flowmeters often have just one wetted part, the housing itself.
In the case of MIB Flowmax, the wetted material is an approved and resistant plastic. Here’s an example of a Suppliers certificate.

Gaps and dead-space

The main reason to go for a single use / disposable component is cleanliness or purity. Contamination in any form or shape is absolutely unacceptable in your process!!
The form and shape of your instrument affect the risk of contamination.
Gaps between components are potential hiding places for bacteria and other unwanted particles or even molecules. Presence of sharp edges and corners or bearing points means an increase of risk. 
Free-bore instruments are always the better option, electromagnetic, Coriolis and Ultrasonic have a comparable ranking.
When considering all details like number of gaps, surface roughness and dead-space, the all-plastic one-piece housing of the ultrasonic disposable FlowMax 242 scores best.

 

Costs

The financial aspect will remain an aspect in the total ranking.
In cases where cost is the most important factor, a turbine-meter will be the better option compared to more advanced instruments.

single use flowmeter
Price-differences between  flowmeters are less important in environments like this.

Bio-pharmaceutical processen have risks which financially have hundreds or thousands times the impact of the instrument value.

Those riscs can partly be prevented by selecting the right equipment for your process.

A clean instrument, free of moving components and with only one wetted part, which reliably measures with high accuracy -even in pulsating flow- is always good value for the money!

 

 

 

Save money by replacing only the neccessary

In  MIB‘s strive to always do the maximum possibe in your advantage, also the cost-impact has been considered.
By designing the instrument with a separate measuring tube, the wetted parts can be exchanged whilst leaving the electronics in place.
In fact it is a single use flowmeasuring tube rather than a single use flowmeters. By providing factory-calibrated measuring tubes, including a dongle with the unique calibration details, you’re ensured of the original accuracy.
In case of a process-change, the nominal bore-size of the measuring tube can be replaced by another size and the matching dongle takes care of the accuracy.

This smart design is freely available and saves you €1.500,= per exchange!

 

Would you prefer a live consult?

Yes please!
Please give some guidelines in the below form and get a relevant and proper advise within one working day. 

Your instrument has been tested, which is certified with the delivery. Optionally, a 3- or 8-point calibration-certificate can be ordered to prove the exact accuracy.

Before you submit:

you may trust an honest advise. If FlowMax is not your best possible solution, I will explain you why that is.

 

 

Single use flowmeter

disposable flowmeter

<english version here>

De Single Use flowmeter is een niche-product wat in de markt inmiddels in meerdere uitvoeringen verkrijgbaar is.
Het is goed dat er diversiteit in het aanbod zit, want er is geen universele oplossing die alleen maar voordelen kent.
Afhankelijk van uw eisen en wensen is te bepalen welk type voor uw applicatie het beste is.
Hierna benoem ik een aantal aspecten die in de afweging een rol spelen.

Eisen en wensen

Als u gaat nadenken over de specifikaties waaraan het instrument moet voldoen zal een aantal zaken voorbij komen.
In deze fase doet u er goed aan de harde eisen te onderscheiden van de softere wensen. Dit is vooral handig als u later uit meerdere opties moet gaan kiezen.

Nauwkeurigheid

Elk type instrument meet anders en met een andere afwijking. 
Elke meetmethode heeft in de uitvoering een maximaal haalbare nauwkeurigheid. Afwijking van de nominale meetwaarde geeft een afwijking in uw proces.
Het is aan u om te bepalen welke nauwkeurigheid noodzakelijk is.
Kijk bij een vergelijk goed naar de grootheid waarin de meetnauwkeurigheid is uitgedrukt. Full Scale (FS) is totaal wat anders dan Measured Value (MV). Hier ga ik graag verder op in, maar in een ander hoofdstuk.
Bij een hoogwaardig instrument als Coriolis of ultrasoon mag u een kalibratiecertifikaat verwachten.

Wetted parts

De zogenaamde ‘wetted parts’ zijn de onderdelen van het instrument die met het medium in aanraking komen.
Bijvoorbeeld bij een turbinemeter is dat de behuizing, de turbine, as, lagering en eventueel afdichtingsmateriaal.
Een electromagnetische flowmeter heeft al minder onderdelen, maar altijd een meetbuis, metalen electroden en afdichtingsmateriaal.
De Coriolis- en de ultrasone flowmeter hebben vaak maar één wetted part, de behuizing zelf. In het geval van de MIB Flowmax is dat ook nog eens een goedgekeurde kunststof. Hier het leveranciers certifikaat.

Spleten en gaps

Bij de overweging om single-use componenten toe te passen speelt vaak hygiëne / zuiverheid een rol. Contaminatie is uit den boze in dit soort processen.
De bouwvorm van uw instrument is van invloed op contaminatie-risico.
Spleten tussen verschillende onderdelen zijn potentiële verstopplaatsen van bacteriën en ongewenste deeltjes. Een lagerpunt van het turbine-asje evenzo. Scherpe hoeken en kantjes zijn evenmin bevorderlijk.
Een instrument met een vrije doorlaat is altijd gunstiger; hier scoren electromagnetisch, coriolis en ultrasoon ongeveer even goed.
Gekeken naar de details, zoals aantal spleten, oppervlakteruwheid en dode hoeken scoort de kunststof ultrasone single use flowmeter het best van de drie.

Kosten

Het prijskaartje is en blijft een aspect van de totale afweging.
In sommige gevallen is de kostprijs de zwaarstwegende factor. Dan wint een turbinemeter het van de geavanceerdere instrumenten.

single use flowmeter
Prijsverschil flowmeter is in deze omgeving ondergeschikt.

Processen in biofarmacie kennen risico’s die in financieel opzicht het honderd- of wel duizendvoudige prijsverschil vertegenwoordigen.

Dat zijn risico’s die deels voorkomen kunnen worden door de juiste equipment voor uw proces te kiezen.


Een clean instrument, zonder bewegende delen en maar één wetted part wat bovendien nog eens superieure meetresultaten geeft, ook bij fluctuerende flow, dat is zijn geld waard!

 

 

 

Bespaar en vervang alleen het hoognodige

Omdat MIB er te allen tijde naar streeft het maximale voor u te doen, is ook naar het kostenplaatje gekeken. Door de meetbuis separaat te produceren kan deze uitgewisseld worden zonder dat dure electronika van de controller vervangen hoeft te worden. Deze blijft dus permanent aanwezig.
In feite spreken we dus niet over een single use flowmeter, maar een single use flowmeetbuis. Doordat de meetbuis al af fabriek gekalibreerd is behoud u de oorspronkelijke nauwkeurigheid waar u aan gewend was.

Dit slim ontwerp kost u niets en het levert u toch weer €1.500,= per wissel op!

Vraag naar de mogelijkheden

 

Liever een adviesgesprek?

Graag!
Geef hieronder in hoofdlijnen uw richting aan, dan bent u verzekerd van een passend advies op korte termijn. 

Uw instrument is getest en daarvan ontvangt u een certifikaat bij de levering. Optioneel is een kalibratiecertifikaat 3 meetpunten, of is een 8-punts kalibratie mogelijk.

 

 

EHEDG sanitaire flowmeter

ehedg ultrasone flowmeter

EHEDG sanitaire flowmeter

Werkt u met processen waar vloeistof nauwkeurig gemeten of gedoseerd moet worden? Waar contaminatie een grote bedreiging is? Waar een grote waarde op het spel staat als het proces verstoord raakt?

Goede kans dat u voor flowmeting en -dosering al eens rondgekeken hebt naar een ideaal instrument.
Of het nu in de chemie is, bio-medische batchproduktie, of ultrapuur gedemineraliseerd water, flowmeting kan altijd op meerdere manieren gedaan worden.

Soms volstaat een simpele turbinemeter en ook de elektromagnetische instrumenten met vrije doorlaat zijn interessant, zowel qua prijs als ook performance. Gaan uw eisen verder dan een basisinstrument dan loont het de moeite om even verder te lezen.

Er is een meetprincipe wat zich bij uitstek leent voor nauwkeurige, schone processen waar u geen enkel risico mag of wilt nemen, terwijl er geen grote aanslag op uw budget wordt gedaan.ehedg sanitaire flowmeter

Ultrasoon vergeleken met Elektromagnetisch

De ultrasone flowmeter heeft net als een elektromagnetische flowmeter (EMF) een vrije doorlaat en geen bewegende delen. Enkele belangrijke voordelen ten opzichte van de EMF zijn:

  • de werking is onafhankelijk van de geleidbaarheid van het medium.
  • zeer hoge sampling rate, extreem nauwkeurig doseren
  • slechts één wetted part, geen spleten, O-ringen of metalen in contact met de vloeistof

Ultrasoon ten opzichte van Coriolis

Een ander alternatief zou een Coriolis-flowmeter kunnen zijn. Deze staan bekend om hun nauwkeurigheid, vrije doorlaat en het mooie aspect van massameting. Is massameting een noodzaak: ga dan voor Coriolis! Enkele positieve kenmerken die Ultrasoon in de weegschaal legt:

  • ongevoelig voor trillingen uit de omgeving
  • vele malen lagere kostprijs
  • kunststof behuizing (bio-medisch approved)

Ultieme reinigbaarheid

Reinigbaarheid van de flowmeter is een ander interessant gegeven. Dankzij de vrije doorlaat en geen bewegende delen kan CIP-cleaning gedaan worden.
Gaat uw proceszekerheid verder dan dit, dan komt de Single Use meetbuis in aanmerking.
Dure elektronica is in een separate behuizing ondergebracht en komt niet in contact met het medium.
Alleen de meetbuis kan vervangen worden, dit bespaart u telkens 40% van de kosten!
Doordat de meetbuis af fabriek gekalibreerd is kan deze zonder bijkomende kalibratie uitgewisseld worden bij het opstarten van een nieuwe batch.

Deutsche Kwalität!

Komen de benoemde functionele aspecten in uw bedrijf aan de orde? Dan zouden we zeker eens contact moeten leggen. Niet onbelangrijk: de instrumenten zijn van Duitse oorsprong en in een breed scala verkrijgbaar.

Stel hieronder uw vraag.

[contact-form-7 id=”5″ title=”Contact form 1″]